SCIOPTA - Real-Time Kernel
User’s Manual Manual Version 4.1 16-9
SCIOPTA - Real-Time Kernel
16 SCONF Kernel Configuration
16.9.1.1 General Tab Parameters
System Name Name of the target system.
Enter the name of your system. Please note that the system module (module 0) in
this system will get the same name.
CPU Type CPU family for the selected architecture.
Compiler C/C++ Compiler selection.
For PowerPC the “GNU” selection is also valid for Windriver.
Maximum Buffer Sizes Maximum number of message buffer sizes.
4, 8 or 16 If a process allocates a message there is also the size to be given. The user just
gives the number of bytes needed. SCIOPTA is not returning the exact amount of
bytes requested but will select one of a list of buffer sizes which is large enough to
contain the requested number. This list can contain 4, 8 or 16 sizes which is con-
figured here in the maximum buffer sizes entry. See 7 “
Pools” on page 7-1.
For the SCIOPTA SCSIM Simulator (win32) only 8 can be selected.
Maximum Modules Maximum number of SCIOPTA modules in the system.
Here you can define a maximum number of modules which can be created in this
system. The maximum value is 127 modules. It is important that you give here a
realistic value of maximum number of modules for your system as SCIOPTA is
initializing some memory statically at system start for the number of modules giv-
en here. See also 4 “
Modules” on page 4-1.
Maximum CONNECTORS Maximum number of CONNECTOR processes in the system.
CONNECTORS are specific SCIOPTA processes and responsible for linking a
number of SCIOPTA systems. The maximum number of connectors in a system
may not exceed 127 which correspond to the maximum number of systems. See
also chapter 12.9 “
Distributed Systems” on page 12-7.
Maximum Int. Vectors Maximum number of interrupt vectors.
This entry is only available for ARM and PowerPC.