CompuLab Ltd. FACE Modules HW Specifications Page 24 of 63
4 FM-SER Serial FACE Module
4.1 Description
FM-SER FACE Module provide various serial connectivity solution and compatible with several Compulab
systems.
Refer to Compatibility Matrix for products fit.
4.2 Highlights
High performance UARTS
Asynchronous baud rates up to 15Mbps
128-byte deep TX/RX FIFOs
Advanced FIFO fill management
RS232, RS485, RS422 operation
Programmable RS485 turn-around delay
450 through 950 software compatibility
Two independent CAN bus controllers implement CAN V2.0B at rate of up to 1Mbps each
Isolated PHY with rated isolation voltage of 2.5 kV RMS
Table 5 FM-SER connectivity
Connectivity
Specifications
RS232 / RS485 / RS422
1
6x RJ-11 jacks functioning as RS232
2
, as half
3
/full-duplex RS485 or RS422
serial ports;
CAN bus
2x RJ-45 jacks functioning as an isolated Controller Area Network (CAN) bus
Notes:
1. The default standard can be configured by jumper E1. See section Serial Ports Configuration.
2. FM-SER is classified as DTE (Data Terminal Equipment) in terms of RS232 standard definition.
3. RS485 half-duplex mode requires special HW/SW adaptation.