CompuLab IPC2 Manual de usuario Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 63
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
CompuLab Ltd. FACE Modules HW Specifications Page 29 of 63
4.5 Configuration
4.5.1 Serial Ports Configuration
Each serial port can be individually configured to act in RS232 mode or RS485 half/full duplex mode. The
configuration is selected in fit-PC3 BIOS setup.
The default selection between RS232 and RS485/RS422 is determined by E1 jumper position. Default
mode determines the power-up state of the Dual Protocol Transceiver. It is applied to all ports and
remains valid in case that software configuration is not performed.
The options of jumper E1 selections are detailed in Table 4.
Table 4 Jumper E1 options
Jumper Position
1
Default Serial Protocol
Assembled
RS232
Removed
RS485 / RS422
Note: The jumper is assembled by default.
Figure 12 Jumper E1 location
After power-up, any individual port can be configured using software controlled SMBus system
management protocol.
4.5.2 CAN Bus power supply
By default, the FM-SER consumes power from the CAN bus.
After power-up, the power supply option can be determined by a GPIO line connected to the motherboard,
and is fully software controlled.
Vista de pagina 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 62 63

Comentarios a estos manuales

Sin comentarios